Gas Logs for Carson Fireplaces, Checked Against the Listing

Ask About Gas Logs

Gas Logs: What Hamlin Does

Many prefab wood fireplaces are approved for a decorative gas log set, but the manual says which kinds. We check that first, then clean the firebox and flue, set the burner, run the gas where a line reaches the hearth, and place the logs to the maker's layout. The damper is clamped partly open so it cannot close on a lit burner. The set and fitting are priced after we look.

Manual checked for allowed log sets
Damper clamped partly open
Burner set and gas connected
Logs placed to the layout
Gas joints leak tested

Whether Your Box Can Take Gas Logs

A gas log set is a burner with ceramic logs on top, set into an open fireplace and fed by a gas line through the side or floor of the firebox. It looks like a wood fire and lights with a key, a switch or a remote. In a brick fireplace the main checks are the size of the opening, a sound flue and a gas line that can reach the hearth. In a factory-built fireplace there is one more check, and it comes first. The maker tested the box for wood, and its manual says whether gas logs may be used in it, which kinds, and where the gas line may enter. Some boxes have a knockout panel in the side for the line. Some say no gas at all. So we read the data plate and the manual before we order a set. Where the box allows it, we fit vented logs, which burn with the damper held open so all the exhaust goes up the pipe and out.

The damper is where most gas log trouble starts. A vented set needs the damper open whenever the burner can light, so we fit a clamp or stop that keeps the blade from closing all the way. That clamp is easy to miss, and someone tidying the fireplace years later may take it out, thinking it is broken. With the clamp gone, the damper can be closed on a lit set, and the exhaust comes into the room. On every service we check the clamp is still there. Sets that burn without any vent use an oxygen sensor on the pilot that shuts them off if the room's air gets thin, and we do not fit them. We would rather every set we fit sends its exhaust outside through the pipe the fireplace was built with. If you already have a set and are not sure which kind it is, the label on the burner or the valve says, and we check it on the first visit along with whether the box was listed for it in the first place.

Fitting a Set and Keeping It Clean

Fitting starts with a clean firebox and flue, so we sweep and inspect first if that has not been done recently. A sweep starts from $395, and a Level 1 is $52. Then the burner goes in, the gas is connected where a line already reaches the hearth, the logs are placed the way the maker's diagram shows, and the damper clamp is set. We light the set, watch the flame, test every joint for leaks and show you how to light it and shut it off. The set and its fitting are quoted in writing after we have seen the fireplace and confirmed the listing allows it. Running a new gas line to the hearth is a separate line on the quote. So is any change the box needs to take the line, such as opening the knockout the maker provides. We never drill the side of a factory-built firebox where the manual does not show a place for it, because that breaks the shell the listing depends on.

A log set needs a yearly service: burner ports cleared, logs checked for soot and cracks and put back in their marked places, the valve and pilot looked at, and the clamp confirmed. A log moved into the flame is the usual cause of soot on the face of the fireplace. If you would rather have heat than looks, an insert gives far more of it, and the inserts page explains the difference. Tell us on the contact form whether the fireplace is metal or brick, and whether there is a gas key or line near the hearth already. A fall service, booked before the first cool evening, keeps an existing set ready for the season. We fit and service gas logs across Carson, Gardena, Long Beach and Bellflower, and in the towns around them.

Four Things on Every Hamlin Chimney Services Job

Plate Read First

Model and maker noted before any part

Listed Parts

Ordered for the unit on the plate

Price on Paper

Set prices stated, the rest written after a look

Photos in the Report

Each finding shown, with the part named

More Fireplace and Chimney Jobs

Chimney Sweep

Metal flue pipe brushed with a poly head that will not score the stainless, plus the firebox and spark screen cleared.

Open the job →

Chimney Inspection

Level 1 or Level 2 under NFPA 211, with the maker's data plate read and the flue sections checked against the listing.

Open the job →

Chimney Repair

Separated pipe joints, rusted chase tops, cracked crowns and loose caps fixed with parts that match the system or the brick.

Open the job →

Fireplace Inspection

Refractory panels, screens, doors, the damper and the outside air kit on a metal fireplace, each checked against the manual.

Open the job →

Fireplace Repair

Cracked refractory panels, stuck dampers and missing screens replaced with listed parts, not cut-to-fit firebrick.

Open the job →

Chimney Level 2 Inspection

Camera through every pipe section and a look at the chase or attic framing, for a sale, a quake or a new appliance.

Open the job →

Chimney Cap Installation

Listed caps for metal pipe and fitted caps for masonry flues, fastened down with mesh that keeps birds and sparks in check.

Open the job →

Chimney Flashing Repair

Metal at the roof joint reset or replaced, whether the chimney is a wood chase or a brick stack, before the rains.

Open the job →

Chimney Masonry Repair

Brick stacks on older houses repointed, crowns recast and spalled faces replaced, each priced after an inspection.

Open the job →

Chimney Rebuilds

A failed brick stack rebuilt from sound masonry, or a rotted chase reframed with new siding, top and listed pipe.

Open the job →

Fireplace Cleaning

Ash out, panels vacuumed, screens and doors cleaned and the damper worked free, with care taken on soft refractory.

Open the job →

Gas Fireplace Cleaning

Burner, pilot, logs and glass on a direct-vent or vented gas unit cleaned, and the outside termination checked.

Open the job →

Gas Fireplace Repair

Dead remotes, a flame that quits and a pilot that will not stay lit, each tested back to the one failed part.

Open the job →

Fireplace Remodel

New faces, mantels and hearths around a metal fireplace, planned to the spacing in its manual before tile is chosen.

Open the job →

Fireplace Inserts

A gas insert placed in a fireplace that is approved for one, vented through its own liner to a new cap.

Open the job →

Pellet Stove Repair

Burn pot, igniter, fans and auger on a pellet stove tested and fixed, with the vent pipe cleaned end to end.

Open the job →

Wood Stove Repair

Door gaskets, glass, baffles and firebrick on a wood stove renewed, and the stovepipe spacing to walls measured.

Open the job →

Chimney Seismic Retrofit

Brick stacks braced or strapped to the house, or taken down to the roofline and finished with a lighter flue.

Open the job →

Chimney Crown Repair

Cracked masonry crowns sealed or recast so water runs off the top instead of soaking down into the brick.

Open the job →

Dryer Vent Cleaning

Lint cleared from the dryer duct and outside hood, with the run checked for crushed or loose sections.

Open the job →

Chimney Liner Installation

Stainless liners for cracked clay flues or for a new gas insert, sized to the appliance and capped at the top.

Open the job →

Chimney Leak Repair

Water traced to the chase top, cap, siding, flashing or crown, then fixed at its source with the right part.

Open the job →

Chimney Waterproofing

A vapor-open water repellent on brick stacks, applied after the crown and joints are sound, so the brick can dry.

Open the job →

Chimney Damper Repair

Stuck, warped or loose damper blades in metal and masonry fireplaces freed, replaced, or swapped for a top-mounted damper.

Open the job →

Chimney Chase Cover

Rusted or flat chase tops replaced with stainless covers that slope water off and fit the pipe and collar.

Open the job →
Call (323) 524-3947